Electrolux refrigerator ice maker not working.
Little or no ice often comes down to a jam, ice frozen around the auger, a locked display or a water supply problem. Electrolux has a short auger procedure, a DI SP ice-jam article and a no-water checklist that also covers the ice maker.

Start with safe observations.
Power the appliance down and pull the plug before any owner check. Beware of standing water and sharp debris. Never touch a wet plug or electrical area, take off service panels, or step beyond your model’s owner guide.
- 1
Clear a jam
DI SP means an ice cube has been stuck in the chute too long. Open the door, look into the chute and remove the blockage. Electrolux's other jam remedy is to take out the bin, let it thaw, empty it, wipe it dry and seat it again.
- 2
Free the auger
Electrolux's auger fix: set the control panel to CRUSHED, remove the ice bucket, press the dispenser paddle for 2 minutes, release it and repeat, three presses in all. That melts ice around the auger motor shaft. Switch back to CUBE, refit the bucket, close the door and test.
- 3
Why ice sticks
Ice that thaws and freezes again around the auger can bind it; Electrolux blames rare use, temperature swings and outages. Cubes can also wedge behind the bin against the ice maker.
- 4
Check the lock
A display in lock mode blocks both water and ice. Keep the lock key pressed for three seconds to release it.
- 5
Water supply and filter
Confirm the refrigerator has power and the water line is correctly installed. The filter must be installed correctly and securely, not frozen or cracked, and primed and purged if it is new.
- 6
After a power outage
Electrolux's outage advice is to cycle that appliance's breaker, then wait a full day for temperatures to settle before judging how much ice you get.
Systems a technician may investigate.
The parts below tie in with this symptom. Seeing it does not prove any one of them has failed.

Ice chute and auger
The ice chute carries cubes from the bin to the dispenser in the door, and the auger in the bin pushes them forward. Electrolux’s DI SP alarm means a cube has sat in the chute too long. A second article covers ice that has melted and refrozen around the auger motor shaft.

Refrigerator water filter
The filter treats the water that feeds the dispenser and ice maker. On Electrolux’s no-water article it is one of four checks: power, water line, locked display and the filter itself. The filter must sit securely, not frozen or cracked, and the brand advises changing it every 6 months.
If the display adds a code.
Keep the exact message.
We have not researched the code meanings for this appliance. Turn to its model manual and attach a photo of the display to your request.
See the research statusRead the related care guide.

Frost in the freezer? Four things to check.
Electrolux describes frost as condensation that freezes where warm air meets air below 32 °F. Check four things: the door and gasket seal, the chute flap, a freezer setting that has drifted below zero, and food sitting across the vents. Book if frost returns.

High Temp on the fridge display? Start with the door and the gasket.
Most Electrolux refrigerator alarms are prompts: PF after a power cut, High Temp when a section passes 26 degrees (freezer) or 55 degrees (fridge), Door Ajar after 5 minutes open, Sb for Sabbath mode and DI SP for an ice jam. OP, SH, SY CE, SY CF and SY EF have no printed meaning.
When observation becomes a service request.
Leave internal testing to a technician.
Book a visit if the ice bin stays empty after you clear the jam, run the auger fix and check the lock, filter and water line. Tell us if DI SP is displayed, and whether water also fails to dispense.
Arrange a diagnosticSources and model boundaries.
These sources back the Electrolux refrigerator ice maker not working guidance. Use the manual for your own model.
- Refrigerators - Auger Fix (KB 1898311)
- Refrigerator Error Code DI SP or DISP - Ice Jam
- Refrigerators - No Water (KB 1900025)
- What do the alarms or error messages mean on my French-Door refrigerator? (KB 1853035)
Follow the guide for your exact model. Consult how we research these pages.
What is the DI SP message?
It means ice has been jammed in the chute for a long time. Open the door, look in the chute and remove the blockage. Electrolux also describes thawing and cleaning the ice bin.
How do I fix the auger?
Switch to CRUSHED, take out the bucket, hold the paddle for 2 minutes, release and repeat, three presses in all. Then return to CUBE, refit the bucket and test.
Can a locked display stop ice?
Yes. While the display is locked, nothing dispenses. Hold the lock key for three seconds to release it.
How long until ice returns after a reset?
Electrolux says the unit needs 24 hours for its temperature to stabilize after a power interruption. Check ice production again after that.
Codes, symptoms, parts and service
Link the message to what to do next.
Electrolux refrigerator ice maker not working
Little or no ice often comes down to a jam, ice frozen around the auger, a locked display or a water supply problem. Electrolux has a short auger procedure, a DI SP ice-jam article and a no-water checklist that also covers the ice maker.
Ice chute and auger
The ice chute carries cubes from the bin to the dispenser in the door, and the auger in the bin pushes them forward. Electrolux’s DI SP alarm means a cube has sat in the chute too long. A second article covers ice that has melted and refrozen around the auger motor shaft.
Refrigerator repair
Book a diagnostic for your model at the appliance.
Find your metro
Office details and the access information to pass on.