Error codes explained

Electrolux dryer E91, E92 and E93: three kinds of board problem

On an Electrolux dryer, E91 means the control board and interface board are not communicating, E92 means they are not compatible and E93 means the machine configuration data failed its check. None is an owner repair, and the model number matters because the sheet's remedies depend on matching parts.

Green electronic control board on a wood desk beside a screwdriver and a blank spiral notepad.
Experienced techniciansWarranty on our workmanshipOEM parts available on orderUpfront pricing, agreed before work
On this page
Key points
  • E91 is communication, E92 is compatibility, E93 is the machine configuration checksum. 1
  • E94 is the cycle configuration checksum and E97 is a program mismatch; both end in replacing the control board. 1
  • The remedies depend on the right interface board, console and control board being fitted together. 1
  • The sheet lists a reset to defaults and an installation cycle, but ties neither to these codes. 1
  • Electrolux's washer sheet reuses the numbers 91 to 97 for similar board problems. 2

What do E91, E92 and E93 mean on an Electrolux dryer?#

E91 is a communication error between the electronic control board and the interface board. E92 is an incompatible protocol between them, and E93 is a machine configuration checksum error. They are the board codes in the dryer chart. 1

Think of the dryer as two boards that talk to each other. The control board carries the relays that switch the motor and the heater. The interface board belongs to the console, where the buttons and the display are. These three codes are about that pair and the data they hold. 1

CodeWhat the sheet calls itPossible conditionsThe sheet's remedy
E91Communication errorWiring, electronic control board or interface board defectiveCheck connections between the two boards; if the wiring is fine, replace the control board or the interface board 1
E92Incompatible protocolControl board incompatible with the interface boardCheck that the correct interface board, console and control board are installed; replace the appropriate hardware 1
E93Machine configuration checksum errorWrong configuration data loaded; interface board, control board or wiring defectiveCheck the correct interface board and console are installed; replace the interface board and/or console 1

How do E91, E92 and E93 differ from each other?#

E91 is a broken link, E92 is a wrong pairing and E93 is stored data that fails its check. All three show on the same family of boards, but each points at a different kind of problem, and the sheet's first step changes with it. 1

For E91 the first step is physical: check the connections between the control board and the interface board. A loose or damaged connection is a plausible cause and a cheap one to find, which is why it is the sheet's first move. Only when the wiring is fine does the sheet move to a board. 1

For E92 the first step is about parts: are the right boards fitted? That is a question for the model number and the parts list, not a meter. 1

For E93 the sheet names "wrong configuration data loaded" first, then the boards or wiring. A checksum is a self-check on stored data, so the code means the dryer read its own settings and they did not add up. 1

What about E94 and E97?#

They are the next two rows on the sheet, and they are the same family of problem. E94 is a cycle configuration checksum error, E97 is a program mismatch, and both end in replacing the electronic control board. 1

E94 carries the same idea as E93 for the cycle data rather than the machine data. E97 says the program loaded does not match what the dryer expects. The sheet's remedy for both rows is a single line: replace the electronic control board. 1

Because those rows are short, the most useful thing you can add is a clear description. Pass on the code, the model, and anything that happened just before it first showed, such as a power cut or a repair.

Can I fix a board code myself?#

No. The sheet's remedies are connection checks inside the cabinet and replacement of boards or a console, and the sheet is labeled for qualified technicians only. An owner cannot test a board. 1

There is one low-risk thing to do. Recall the code so it is accurate, and note whether it appears at once on power-up or only after a button press. The recall is the same as for any code: wake the dryer, then hold cancel and start/pause for 6 seconds. 1

Two fingertips pressing two buttons together on a white dryer panel with a lit blank display.
Recall the stored code before the visit. 1

The sheet also lists a reset to default settings, which is a 6-second hold of the temperature and dryness buttons, and an installation cycle run on an empty drum. 1 It does not say to use either for E91, E92 or E93. Treat them as technician tools, and do not experiment on a dryer showing a board code.

Is the code I recall a current one?#

Not always. The dryer keeps the last code until someone clears the history, and the sheet's way to clear it is a deliberate 3-second hold of the far left key under the display together with cancel. 1 So a recalled E91 may be old, and the dryer may be working properly today.

If the code is old and the dryer is behaving, say so. It changes how we approach the visit.

What happens during a visit?#

The technician starts with the history. Diagnostic Mode is entered by pressing cancel, waking the control with another button, turning the selector to the far left cycle and holding cancel with the far left key for 3 seconds. All the lights then flash. 1

From there the selector steps through tests: a lights and buttons test at position 0, motor and heater checks in the middle, the last 5 error codes at position 9 and the software version at position 10. 1 Exiting is done by unplugging the dryer for 5 to 8 seconds, or by returning the selector to the start position and holding cancel with the far left key for 6 seconds. 1

The software version is one more detail the technician can note. Then the connections are checked, and a board or console is replaced only if the checks call for it.

Why does the model number matter so much?#

Two of the three rows are about the right parts being fitted: E92 and E93 both tell the technician to check that the correct interface board and console are installed. A board that fits the connector may still be the wrong board. 1

So the label on the frame is the key to the whole job. With the model number we can match the interface board, the console and the control board before the visit, rather than finding a mismatch on the day. If anything was replaced earlier, say so. A part that was swapped in for a different model is a clean explanation for E92, and the sheet's remedy for it is to replace the appropriate hardware. 1

A technician can also read the stored history. In Diagnostic Mode the last 5 error codes sit at one test position and the software version at the next. 1 Both help to decide whether the code is new or old.

Green circuit board on a wooden bench beside a small screwdriver and a blank spiral notepad.
The control board and the interface board are a matched pair. 1

Do washers use the same numbers?#

Electrolux's washer sheet uses the same range for similar problems, but it is a separate table. The washer chart lists 91 as a protocol incongruence error, 92 as a mother board protocol incongruence, 93 as a console or main board problem and 94, 97 and 98 as related configuration rows. 2

On the washer sheet the display column marks 91, 93, 94, 97 and 9C as shown to the user and 92 and 98 as not shown. 2 The point for a dryer owner is simple: do not carry a washer meaning across. Each appliance has its own chart, and our code pages are kept apart for that reason. See the dryer code library for the full Ceres list.

Once you know the family, the recall and families guide shows where the board codes sit among the others.

Sources#

  1. Dryer Tech Data Sheet, P/N 137265000B (1202)Electrolux (technician sheet; retailer-hosted copy) · P/N 137265000B (1202); Canadian SKU EIMED6CJIW; original file dated 2009 · pp. 2-3 (Error Code Chart E91 to E97; Diagnostic Mode, reset and installation cycle)
  2. Washer Tech Data Sheet, A11200302 (1803)Electrolux (technician sheet; retailer-hosted copy) · A11200302 (1803); 2018, 300/400/500/600 series (EFLS527UTT and EFLS627UTT copies are byte-identical) · p. 4 (Washer Error Codes, 91 to 9E)

Here to help

Good questions.
Clear answers.

Talk to our team
What is the difference between E91 and E92?

E91 means the control board and the interface board are not communicating, with wiring or either board as the cause. E92 means the two boards are not compatible with each other. One is a broken link, the other a wrong pairing. See source 1, page 2.

Why would a dryer have a configuration error?

The sheet lists wrong configuration data being loaded, a defective board or defective wiring. E93 covers the machine configuration and E94 the cycle configuration. Both rows are about stored settings failing a check. See source 1, page 2.

Will unplugging the dryer clear E91?

The sheet gives no reset step for E91, E92 or E93. Unplugging the dryer does no harm and shows whether the code is steady, but the sheet's remedies are connection checks and board replacement. See source 1, page 2.

Can a new board cause E92?

The sheet says E92 comes from a control board that is incompatible with the interface board, and it tells the technician to check that the correct parts are installed. A mismatched pair is exactly that condition. See source 1, page 2.

Is E97 related to E93?

They sit in the same family and share the idea of wrong configuration data. E93 is the machine configuration checksum, E97 is a program mismatch. E97's remedy is to replace the electronic control board. See source 1, page 2.