What it means
E63 is a heater to earth ground failure on Electrolux's dryer chart: the heating element or its wiring is shorted to the cabinet. Unplug the dryer and do not run it again until a technician has checked the heater.
Electrolux dryer E63 / Heating
E63 is a heater to earth ground failure on Electrolux's dryer chart: the heating element or its wiring is shorted to the cabinet. Unplug the dryer and do not run it again until a technician has checked the heater.
Also shown as E63
E63 is a heater to earth ground failure on Electrolux's dryer chart: the heating element or its wiring is shorted to the cabinet. Unplug the dryer and do not run it again until a technician has checked the heater.
Do not open the cabinet or touch the heater.
E63 appears at all.
Your checklist, kept on this device

A heater shorted to the cabinet can make the metal live. Leave it unplugged and do not touch the cabinet while it is powered.

The chart leaves no owner step for E63. Another cycle could repeat the short.

If the breaker tripped when the dryer heated, tell us.

Without opening anything, note scorch marks near the plug or cord.

The chart checks the heater coils and connections for shorts to the cabinet and replaces the heater or wiring.
Send us the model and the checks you have done, and open your request here.
Book a visit

A simplified drawing, since layouts differ between models. Pick an outlined part for its photo and the related check.

Component reference
The heating element is the set of heater coils that warm the air in an Electrolux dryer.
Read the definitionThe heater, or the wiring to it, is touching earth or the cabinet. The chart's row reads heater to earth ground, with a defective heating element or wiring.
Read the supporting manualCheck the heater coils and connections for short circuits to the cabinet, then replace the heater and/or the wiring and retest.
Read the supporting manualE61 and E64 mean the dryer may not heat. E63 means electricity is going somewhere it should not.
Read the supporting manualE64 is the opposite case: an open circuit. Both concern the heater and wiring.
Read the supporting manualManufacturer document
Electrolux (technician sheet; retailer-hosted copy)
P/N 137265000B (1202); Canadian SKU EIMED6CJIW; original file dated 2009 / sheet p.1 (Error Code Chart)
Row E63 of the dryer chart, page 1.
Potentially. A heater shorted to the cabinet is why the dryer should stay unplugged.
We would not use the dryer at all until it has been checked.
The chart does not say. A breaker that trips when the dryer heats is a sign to report.
For E63, the model, whether gas or electric and anything you noticed when the code appeared.
Codes, symptoms, parts and service
E64 is an open circuit in the heater on Electrolux's dryer chart: the heating element or its wiring is defective. The dryer may tumble with no heat. Check the cycle and the breakers, then book a technician.
Most dryer noise has a simple source: coins or buckles in the drum, a loose pedestal, shipping bolts still in place or a dryer that is out of level. Electrolux also lists sounds that are normal, such as the chime at the end of a cycle.
The heating element is the set of heater coils that warm the air in an Electrolux dryer. Electrolux's dryer chart names the element or its wiring for E63 (heater to earth ground) and E64 (heater open circuit). If the drum turns but the air stays cold, check the cycle and both house breakers first.
Book a diagnostic for your model at the appliance.
Office details and the access information to pass on.