What it means
E66 means a thermal limiter is open on Electrolux's dryer chart: the outlet limiter has tripped, or on gas models the inlet limiter, or the wiring is defective. Unplug the dryer and book a technician; do not bridge the limiter.
Electrolux dryer E66 / Heating
E66 means a thermal limiter is open on Electrolux's dryer chart: the outlet limiter has tripped, or on gas models the inlet limiter, or the wiring is defective. Unplug the dryer and book a technician; do not bridge the limiter.
Also shown as E66
E66 means a thermal limiter is open on Electrolux's dryer chart: the outlet limiter has tripped, or on gas models the inlet limiter, or the wiring is defective. Unplug the dryer and book a technician; do not bridge the limiter.
A thermal limiter opens after a high-temperature event.
E66 appears, or the dryer shuts off mid-cycle and is hot.
Your checklist, kept on this device

A thermal limiter opens after a high-temperature event. Let the dryer cool fully.

Restricted airflow is behind most overheating. Clear the screen and check the duct for crushing. [2]

The chart separates gas from electric for the inlet limiter. Tell us which you have.

A thermal limiter is a one-shot safety cutout. Bridging it removes the dryer's overheat protection.

The chart checks the outlet limiter for continuity (and the inlet limiter on gas models), then looks for evidence of the high-temperature event.
Send us the model and the checks you have done, and open your request here.
Book a visit


A simplified drawing, since layouts differ between models. Pick an outlined part for its photo and the related check.

Component reference
The thermal limiter is a temperature safety part in the dryer’s heated air path.
Read the definition
Component reference
The lint screen, also called the lint filter, catches lint from the air leaving an Electrolux dryer.
Read the definitionThe chart lists thermal limiter open circuit, with the outlet limiter tripped, the inlet limiter tripped (gas only) or defective wiring.
Read the supporting manualCheck the outlet thermal limiter for continuity, and the inlet one too on a gas model. If a limiter is open, look for evidence of a high-temperature event and resulting damage; if none, replace the limiter and retest.
Read the supporting manualE65 counts high limit thermostat trips; E66 is a thermal limiter that has opened. Both come from overheating.
Read the supporting manualThe chart replaces it. It is not a resettable part.
Read the supporting manualManufacturer document
Electrolux (technician sheet; retailer-hosted copy)
P/N 137265000B (1202); Canadian SKU EIMED6CJIW; original file dated 2009 / sheet p.1 (Error Code Chart)
Manufacturer document
Electrolux / Owner Center knowledge base (owner.electrolux.com)
Owner Center article, cached 10.11.2026 (no edition date printed) / article text
Row E66 of the dryer chart, page 1, and the lint screen article (KB 1847456). The inlet-limiter check applies to gas models.
The chart does not say. It asks the technician to look for evidence of a high-temperature event, and a blocked vent is the usual suspect.
An open limiter means the dryer cut off to protect itself. The risk is in running it again without finding the cause.
No. An open thermal limiter means the safety cutout has already acted once, so leave the dryer unplugged until a technician has found the cause.
The model, gas or electric, the vent length and when the vent was last cleaned.
Codes, symptoms, parts and service
E65 means the high limit thermostat has tripped too many times, per Electrolux's dryer chart. The chart lists a restricted vent first, then the thermostat or, on electric models, the inlet thermal limiter. Clean the lint screen and vent, then book a technician.
Most dryer noise has a simple source: coins or buckles in the drum, a loose pedestal, shipping bolts still in place or a dryer that is out of level. Electrolux also lists sounds that are normal, such as the chime at the end of a cycle.
The thermal limiter is a temperature safety part in the dryer’s heated air path. When it opens, the circuit stops. Electrolux’s dryer sheet names the outlet limiter (plus an inlet limiter on gas models) behind E66, and an inlet limiter on electric models behind E65.
Book a diagnostic for your model at the appliance.
Office details and the access information to pass on.