What it means
E72 means the outlet control thermistor is shorted, per Electrolux's dryer chart. A technician checks its resistance, which should be 4.9K to 6.2K ohms at room temperature, and the wiring for a short. Book a visit.
Electrolux dryer E72 / Sensors
E72 means the outlet control thermistor is shorted, per Electrolux's dryer chart. A technician checks its resistance, which should be 4.9K to 6.2K ohms at room temperature, and the wiring for a short. Book a visit.
Also shown as E72
E72 means the outlet control thermistor is shorted, per Electrolux's dryer chart. A technician checks its resistance, which should be 4.9K to 6.2K ohms at room temperature, and the wiring for a short. Book a visit.
If the exhaust feels very hot or the dryer shuts off early, note which.
E72 returns or the dryer overheats.
Your checklist, kept on this device

If the exhaust feels very hot or the dryer shuts off early, note which. The control relies on this sensor.

Keep airflow normal in the meantime. [2]

A short across the thermistor connections may be in the wiring, not the sensor.

Tap any button other than Cancel to wake the dryer, then keep Cancel and Start/Pause pressed together for six seconds.

The chart checks resistance, then checks the wiring for a short across the connections, then replaces the thermistor and/or wiring.
Send us the model and the checks you have done, and open your request here.
Book a visit


A simplified drawing, since layouts differ between models. Pick an outlined part for its photo and the related check.

Component reference
Control thermistors are the temperature sensors that tell the dryer how hot the air is.
Read the definition
Component reference
The lint screen, also called the lint filter, catches lint from the air leaving an Electrolux dryer.
Read the definitionThe outlet control thermistor reads as a short circuit. The chart lists the thermistor or its wiring as defective.
Read the supporting manualA technician checks the resistance (4.9K to 6.2K ohms at 68 to 77 F is normal) and checks the wiring for a short across the thermistor connections.
Read the supporting manualE71 is open circuit; E72 is short circuit. Same sensor.
Read the supporting manualUse short timed cycles only if it dries normally; stop if it gets unusually hot.
Read the supporting manualManufacturer document
Electrolux (technician sheet; retailer-hosted copy)
P/N 137265000B (1202); Canadian SKU EIMED6CJIW; original file dated 2009 / sheet p.2 (Error Code Chart)
Manufacturer document
Electrolux / Owner Center knowledge base (owner.electrolux.com)
Owner Center article, cached 10.11.2026 (no edition date printed) / article text
Row E72 of the dryer chart, page 2.
The chart lists no vent condition for E72, only the thermistor and wiring.
Resistance is the measure: 4.9K to 6.2K ohms at room temperature. The control converts it into a temperature.
It may after a restart, but a short in the wiring or the thermistor is still there and returns the code when the dryer next runs.
The model, how hot the exhaust is and whether E71 also appeared.
Codes, symptoms, parts and service
E71 means the outlet control thermistor is open circuit, per Electrolux's dryer chart. A technician checks its resistance, which should be 4.9K to 6.2K ohms at room temperature, and the wiring. Book a visit; the dryer may stop or misjudge heat.
Most dryer noise has a simple source: coins or buckles in the drum, a loose pedestal, shipping bolts still in place or a dryer that is out of level. Electrolux also lists sounds that are normal, such as the chime at the end of a cycle.
Control thermistors are the temperature sensors that tell the dryer how hot the air is. Electrolux’s sheet names an outlet, an inlet and an exhaust thermistor. E71 to E74 mean an open or shorted sensor circuit, and EF1 and EF3 list them among the causes.
Book a diagnostic for your model at the appliance.
Office details and the access information to pass on.