What it means
E74 means the inlet control thermistor is shorted, per Electrolux's dryer chart. A technician checks its resistance, which should be 47K to 66K ohms at room temperature, and the wiring for a short. Book a visit.
Electrolux dryer E74 / Sensors
E74 means the inlet control thermistor is shorted, per Electrolux's dryer chart. A technician checks its resistance, which should be 47K to 66K ohms at room temperature, and the wiring for a short. Book a visit.
Also shown as E74
E74 means the inlet control thermistor is shorted, per Electrolux's dryer chart. A technician checks its resistance, which should be 47K to 66K ohms at room temperature, and the wiring for a short. Book a visit.
A thermistor shorted at the inlet can make heating erratic.
E74 returns.
Your checklist, kept on this device

A thermistor shorted at the inlet can make heating erratic. Note whether the dryer runs hot, cold or stops.

Keep airflow normal in the meantime by emptying the lint screen after each load, as Electrolux advises.

The short may be in the wiring, not the sensor.

Press any button except Cancel and then hold Cancel and Start/Pause for 6 seconds.

The chart checks resistance and the connections for a short, then replaces the thermistor and/or wiring.
Send us the model and the checks you have done, and open your request here.
Book a visit


A simplified drawing, since layouts differ between models. Pick an outlined part for its photo and the related check.

Component reference
Control thermistors are the temperature sensors that tell the dryer how hot the air is.
Read the definition
Component reference
The lint screen, also called the lint filter, catches lint from the air leaving an Electrolux dryer.
Read the definitionThe inlet control thermistor reads as short circuit. The chart lists the thermistor or its wiring as defective.
Read the supporting manualResistance against 47K to 66K ohms at 68 to 77 F, and the wiring for a short across the thermistor connections.
Read the supporting manualE73 is open; E74 is shorted. Same part, same range, same fix.
Read the supporting manualTreat it as a reason to watch the dryer. If it overheats, stop using it.
Read the supporting manualManufacturer document
Electrolux (technician sheet; retailer-hosted copy)
P/N 137265000B (1202); Canadian SKU EIMED6CJIW; original file dated 2009 / sheet p.2 (Error Code Chart)
Manufacturer document
Electrolux / Owner Center knowledge base (owner.electrolux.com)
Owner Center article, cached 10.11.2026 (no edition date printed) / article text
Row E74 of the dryer chart, page 2.
The chart names wiring as a possible condition, so a connection problem is on the list.
E72 is the outlet thermistor shorted. Different sensor.
The chart gives its range at 68 to 77 F. It names no ambient cause.
For E74, the model number and any odd heating you noticed, such as very hot exhaust or cycles that end early.
Codes, symptoms, parts and service
E73 means the inlet control thermistor is open circuit, per Electrolux's dryer chart. A technician checks its resistance, which should be 47K to 66K ohms at room temperature, and the wiring. Book a visit.
Most dryer noise has a simple source: coins or buckles in the drum, a loose pedestal, shipping bolts still in place or a dryer that is out of level. Electrolux also lists sounds that are normal, such as the chime at the end of a cycle.
Control thermistors are the temperature sensors that tell the dryer how hot the air is. Electrolux’s sheet names an outlet, an inlet and an exhaust thermistor. E71 to E74 mean an open or shorted sensor circuit, and EF1 and EF3 list them among the causes.
Book a diagnostic for your model at the appliance.
Office details and the access information to pass on.