Start from the symptom

Electrolux dryer runs but does not heat.

A drum that turns without heat often means one of the two house circuits feeding an electric dryer has tripped. Electrolux also lists the cycle choice, a 240-volt supply and, on gas models, the gas valve, the propane tank and the air around the dryer.

Last reviewed

Hand pressing on a heap of damp dark clothes inside an open dryer drum to check whether the fabric is still wet
Experienced techniciansWarranty on our workmanshipOEM parts available on orderUpfront pricing, agreed before work

Start with safe observations.

Power the appliance down and pull the plug before any owner check. Beware of standing water and sharp debris. Never touch a wet plug or electrical area, take off service panels, or step beyond your model’s owner guide.

  1. 1

    Look at both breakers or fuses

    An electric dryer uses two house circuits or fuses. When one is tripped or blown, the drum can still turn while the heater gets nothing. Switch the breaker back on, or swap in a fuse of identical rating, never a larger one.

  2. 2

    Read the cycle and temperature

    On Air Fluff, or the air-only temperature, the drum turns with no heat at all. Electrolux suggests low or medium heat with a normal dry setting.

  3. 3

    Voltage at the outlet

    Electrolux wants a qualified electrician to confirm that the outlet supplies 240 volts. Its drying-time article adds that 208 volts, rather than 240, makes drying take longer.

  4. 4

    Gas dryer: supply

    Confirm the shutoff valve on the gas line is open. On propane, check that the tank is not empty. After an interruption in natural gas service, Electrolux says to call the gas company. If you smell gas, leave the dryer off, go outside and call your gas utility.

  5. 5

    Gas dryer: room around it

    The burner needs air to run properly. Keep laundry and rugs away from the front and the back of the dryer.

  6. 6

    Weak heat rather than none

    Clean the lint screen after every use, wipe the moisture sensor bars with rubbing alcohol if softener sheets left a film, and clear the exhaust duct and hood. Do not operate a gas dryer lacking a duct that carries exhaust outside; carbon monoxide is the danger.

  7. 7

    Heat codes

    On Electrolux's dryer sheet, E61 is a heater relay failure, E64 an open heater circuit and E66 an open thermal limiter. All three need a technician.

When observation becomes a service request.

Leave internal testing to a technician.

If both breakers are fine, the settings are right and the dryer still will not heat, or if E61, E64 or E66 appears, book a technician. We can test the heater circuit and the thermal limiter. With any gas smell, stop first and call the gas utility.

Arrange a diagnostic

Sources and model boundaries.

These sources back the Electrolux dryer runs but does not heat guidance. Use the manual for your own model.

  • My dryer is running, but does not seem to be heating. What should I do? (KB 1853007)
  • Dryer - Not Drying and Extended Drying Time (KB 1853008)
  • Dryer Tech Data Sheet, P/N 137265000B (1202)

Follow the guide for your exact model. Consult how we research these pages.

Here to help

Good questions.
Clear answers.

Talk to our team
My dryer turns yet stays cold. Why?

On an electric dryer, one tripped breaker or blown fuse can leave the drum turning with no power to the heater. Check both house circuits first.

Can the Air Fluff setting cause no heat?

Yes. With Air Fluff the laundry tumbles but is not heated. Pick low or medium heat with a normal dry setting and start again.

My gas dryer does not heat. What should I check?

Open the gas valve and, on propane, look at the tank. Leave room around the dryer for burner air. Smell gas? Stop, go outside and call your gas utility.

Does E64 mean the heating element failed?

The sheet describes E64 as an open circuit in the heating element or its wiring. It points at the heater circuit, and a technician confirms which part has failed.

Let’s take care of it.

Premium appliances deserve